Gow Mac Gc Manual

Gow mac gc manual software

Gow-mac Series 400 Gas Chromatograph Manual

  1. GOW-MAC Instrument Series 580 Gas Chromatograph. GOW-MAC Series 580 Isothermal Gas Chromatograph with Thermal Conductivity Detector. System includes: 580 Mainframe, 110V, 60 Hz. Cables, Multi Box, PCI Card Manuals $5,499.00. Perkin Elmer AutoSystem XL Gas Chromatograph $790.00. Varian 3900 Gas.
  2. Home › Forums › 'Zebra' Adidas Yeezy Boost 350 V2 Restock Will Reportedly Be More Available This Time › Gow mac leak detector manual Tagged: detector, Gow, leak, mac, manual 0 replies, 1 voice Last updated by Anonymous 2 months, 1 week ago Viewing 1 post (of 1 total) Author Posts May 19, 2019 at 7:51.
  3. Technical Description. The microLAB FS-528 is an excellent readout unit for popular Gow-Mac gas chromatographs. A simple connection with the Gas Chromatography Cable permits collection and integration of GC peaks with a sensitivity range of 50 mV full scale.
  4. Series 580 - Gas Chromatograph by GOW-MAC Instrument Co. The Series 580 Gas Chromatograph sets the standard for reliable performance in a wide range of applications. So impressive has the performance of this GC been, that many 580 users refer to it.
  5. Operation of the GOWMAC Series 350 Gas Chromatograph 1. Turn on the chart recorder. Turn the 'DET POWER' switch to the on position, and turn the 'CURRENT' knob fully clockwise. The remainder of the setup will have been done by the lab staff. Turn the 'ATTENUATOR' knob on the gc to '4', and use the 'ZERO' knob on the chart.

Model Series 580 - Gas Chromatograph

Gow mac 400

7 11/07 GOW-MAC Instrument Co. Series 23-550 Total Hydrocarbon Analyzer 5 IMPORTANT WARNING THIS MANUAL MUST BE CAREFULLY READ BY ALL INDIVIDUALS WHO HAVE OR WILL HAVE THE RESPONSIBILITY FOR INSTALLING, USING, OR SERVICING. GOW-MAC® Series 590 DID Gas Chromatograph Detector The Series 590 DID GC contains a single, GOW-MAC® patented. discharge ionization detector (DID) which is ® ® products GOW-MAC Instrument Co. ® GOW-MAC Instrument Co., Ltd.

From Instruments - Gas Chromatographs

The Series 580 Gas Chromatograph sets the standard for reliable performance in a wide range of applications. So impressive has the performance of this GC been, that many 580 users refer to it as 'The Workhorse' instrument of their laboratory. The Series 580 GC can be customized to fit the exact requirements your application requires, utilizing either a TCD, FID, DID or PID detector.

Manual
  • Most popular related searches

Features

  • Isothermal Operation
  • Detectors: TCD, FID, DID, or PID
  • Direct On-Column Injection or Gas Sample Valve: packed, capillary — split/splitless
  • Single or Dual Column
  • Accommodates 1/8” or 1/4” o.d. metal, 6 mm glass, or capillary columns
  • Column temperature range: ambient to 400 °C
  • Column oven temperature protection circuit
  • Readout: 3-1/2 digit LED digital display
  • Independent Temperature Controls for Column Oven, Detector, Injection Ports
  • On-line monitoring and valve manipulation by software or linking workstation
  • Microscale Compatible: heated, threaded exit ports, (optional — TCD only)
  • Signal Amplifier, x10 (TCD — optional)
  • Choice of standard or corrosion resistant system
  • Installation: bench or 19” rack mount
  • Power: 110-220 V, 50-60 Hz